The PBM Industrial 24 Volt 200 Amp 3 Phase Battery Chargers are well built for forklift or other industrial applications where a smart charger of high amp output is appropriate, and three phase input is desired or required because of availability. There are no manual timers to mess with, as the internal charge regulation is done by the microprocessor for a full charge every time. Economical yet powerful enough to handle most forklift applications, these chargers are designed to withstand continuous duty use quietly and efficiently. The linear transformer and microprocessor control give years of trouble free service. They have a 4 digit LDC display with 12 functions. These units complete the charge and go into a maintenance mode. For wet cell lead acid batteries, 1000 to 1400 AH. Some of the 3 phase units require lead time.
Part#: 30-373 PBM 24 Volt 200 Amp 3 Phase Charger $1895 CALL! |
Specifications: | Features: | |
Dim (LxWxH): | 22.1 x 26.2 x 21.1 | Ferroresonant Design |
AC Input: | 208V/240V/480V/600V | Microprocessor Control |
AC Current Draw: | 19.5A/16.9A/8.5A/6.8A | LCD Display |
Output: | 24 Volt 200 Amp | Three Phase Input |
Warranty: | 5 Years | |
Approvals: | UL, CUL, CE |
Technical features:
• Three-phase input supply: 208/240/480 VAC - Frequency 60 Hz.
• Different power supply voltages available on request.
• Transformer adjustments to ±5% VAC.
• Tropicalized stray-flux transformer, copper windings with double enamel insulation, class H, impregnated with non-toxic resins, kiln-dried.
• Transformer with UL recognized insulation system which ensures high reliability even in difficult operating conditions.
• Low voltage control circuit (24 VAC).
• Overload cutout on transformer.
• Rectifier bridge equipped with interference suppressing filters.
• Protection fuses on mains input and D.C. output.
• Final acceptance test conforming to safety regulations.
• Complete with charging cables and battery connectors.
• Power cord to be installed by the customer.
• Can be stacked up to three units high.
• Charging with decreasing current to 2.4 V/cell, then gas charging stage begins (adjustable).
• Time controlled gas charging, adjustable by dip switch (3 hours standard).
• Equalizing charge automatically performed 60 minutes after last charge cycle.